CVE-2026-8032
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P
Summary
A flaw has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. The impacted element is an unknown function of the file /cdemos/echs/priv/echs.js. This manipulation of the argument ADMIN_KEY causes hard-coded credentials. The attack is possible to be carried out remotely. The exploit has been published and may be used. Upgrading to version 5.7.1 is sufficient to resolve this issue. The affected component should be upgraded. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.
Affected Software
| Vendor | Product | Version Range | Status |
|---|---|---|---|
| PicoTronica | e-Clinic Healthcare System ECHS | 5.7 | affected |
| PicoTronica | e-Clinic Healthcare System ECHS | 5.7.1 | unaffected |
Weaknesses
- CWE-798: Hard-coded Credentials
- CWE-259: Use of Hard-coded Password
ADP Enrichment
CISA ADP Vulnrichment
- SSVC:
- Exploitation: poc
- Automatable: yes
- Technical Impact: partial
References
- https://vuldb.com/vuln/361358
- https://vuldb.com/vuln/361358/cti
- https://vuldb.com/submit/800792