CVE-2026-5397
7.8
CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H
Summary
It has been identified that a vulnerability (CWE-427) exists in the UPS (Uninterruptible Power Supply) management application, whereby improper permissions on the installation directory allow a malicious actor to place a DLL that is then executed with administrator privileges.
If a malicious DLL is placed in the installation directory of this product, there is a possibility that the malicious DLL may be executed by exploiting the product’s behavior of loading missing DLLs from the same directory as the executable during service startup.
Affected Software
| Vendor | Product | Version Range | Status |
|---|---|---|---|
| OMRON SOCIAL SOLUTIONS CO., Ltd. | PowerAttendant Standard Edition | 2.1.2 or lower | affected |
Weaknesses
- CWE-427: CWE-427 Uncontrolled Search Path Element
ADP Enrichment
CISA ADP Vulnrichment
- SSVC:
- Exploitation: none
- Automatable: no
- Technical Impact: total
References
- https://www.omron.com/jp/ja/inquiry/data/OMSR-2026-001_ja.pdf
- https://www.omron.com/global/en/inquiry/data/OMSR-2026-001_en.pdf
Feedback
Was this page helpful?
Glad to hear it! Please tell us how we can improve.
Sorry to hear that. Please tell us how we can improve.