CVE-2026-18272
6.8
CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Kenwood DNR1007XR startUpdateProcess Command Injection Vulnerability. This vulnerability allows physically present attackers to execute arbitrary code on affected installations of Kenwood DNR1007XR devices. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the startUpdateProcess method. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-28981.
Affected Software
| Vendor | Product | Version Range | Status |
|---|---|---|---|
| Kenwood | DNR1007XR | 1.7.0003.1000 | affected |
Weaknesses
- CWE-78: CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
References
- https://www.zerodayinitiative.com/advisories/ZDI-26-489/
- https://www.kenwood.com/cs/ce/mm/firmware/2020/2020f/eng.html
Feedback
Was this page helpful?
Glad to hear it! Please tell us how we can improve.
Sorry to hear that. Please tell us how we can improve.