CVE-2026-17494
8.2
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Summary
IBM Power Systems Firmware FW1120.00, and FW1110.00 through FW1110.30 is affected by a vulnerability in the interface between the BMC and the host system. An attacker with service access to the BMC can send a specially crafted command, allowing arbitrary code to be executed on the host system, giving full control over the host system and all hosted partitions, resulting in a confidentiality, integrity, and availability impact.
Affected Software
| Vendor | Product | Version Range | Status |
|---|---|---|---|
| IBM | Power Systems Firmware | FW1120.00 | affected |
| IBM | Power Systems Firmware | FW1110.00 <= FW1110.30 | affected |
Weaknesses
- CWE-121: CWE-121 Stack-based Buffer Overflow
ADP Enrichment
CISA ADP Vulnrichment
- SSVC:
- Exploitation: none
- Automatable: no
- Technical Impact: total
References
Feedback
Was this page helpful?
Glad to hear it! Please tell us how we can improve.