CVE-2025-69425

Summary

The Ruckus vRIoT IoT Controller firmware versions prior to 3.0.0.0 (GA) expose a command execution service on TCP port 2004 running with root privileges. Authentication to this service relies on a hardcoded Time-based One-Time Password (TOTP) secret and an embedded static token. An attacker who extracts these credentials from the appliance or a compromised device can generate valid authentication tokens and execute arbitrary OS commands with root privileges, resulting in complete system compromise.

Affected Software

VendorProductVersion RangeStatus
RUCKUS NetworksvRIoT IoT Controller2.3.0.0 (GA) < 3.0.0.0 (GA)affected
RUCKUS NetworksvRIoT IoT Controller2.3.1.0 (MR) < 3.0.0.0 (GA)affected
RUCKUS NetworksvRIoT IoT Controller2.4.0.0 (GA) < 3.0.0.0 (GA)affected

Weaknesses

  • CWE-306: CWE-306 Missing Authentication for Critical Function
  • CWE-798: CWE-798 Use of Hard-coded Credentials

ADP Enrichment

CISA ADP Vulnrichment

  • SSVC:
  • Exploitation: none
    • Automatable: yes
    • Technical Impact: total

References