CVE-2025-69425
10
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
Summary
The Ruckus vRIoT IoT Controller firmware versions prior to 3.0.0.0 (GA) expose a command execution service on TCP port 2004 running with root privileges. Authentication to this service relies on a hardcoded Time-based One-Time Password (TOTP) secret and an embedded static token. An attacker who extracts these credentials from the appliance or a compromised device can generate valid authentication tokens and execute arbitrary OS commands with root privileges, resulting in complete system compromise.
Affected Software
| Vendor | Product | Version Range | Status |
|---|---|---|---|
| RUCKUS Networks | vRIoT IoT Controller | 2.3.0.0 (GA) < 3.0.0.0 (GA) | affected |
| RUCKUS Networks | vRIoT IoT Controller | 2.3.1.0 (MR) < 3.0.0.0 (GA) | affected |
| RUCKUS Networks | vRIoT IoT Controller | 2.4.0.0 (GA) < 3.0.0.0 (GA) | affected |
Weaknesses
- CWE-306: CWE-306 Missing Authentication for Critical Function
- CWE-798: CWE-798 Use of Hard-coded Credentials
ADP Enrichment
CISA ADP Vulnrichment
- SSVC:
- Exploitation: none
- Automatable: yes
- Technical Impact: total
References
- https://support.ruckuswireless.com/security_bulletins/336
- https://www.vulncheck.com/advisories/ruckus-vriot-iot-controller-hardcoded-tokens-rce