CVE-2024-39530

Summary

An Improper Check for Unusual or Exceptional Conditions vulnerability in the chassis management daemon (chassisd) of Juniper Networks Junos OS allows an unauthenticated, network-based attacker to cause a

Denial-of-Service (DoS).

If an attempt is made to access specific sensors on platforms not supporting these sensors, either via GRPC or netconf, chassisd will crash and restart leading to a restart of all FPCs and thereby a complete outage.

This issue affects Junos OS:

  • 21.4 versions from 21.4R3 before 21.4R3-S5,
  • 22.1 versions from 22.1R3 before 22.1R3-S4,
  • 22.2 versions from 22.2R2 before 22.2R3,
  • 22.3 versions from 22.3R1 before 22.3R2-S2, 22.3R3,
  • 22.4 versions from 22.4R1 before 22.4R2.

This issue does not affect Junos OS versions earlier than 21.4.

Affected Software

VendorProductVersion RangeStatus
Juniper NetworksJunos OS21.4R3 < 21.4R3-S5affected
Juniper NetworksJunos OS22.1R3 < 22.1R3-S4affected
Juniper NetworksJunos OS22.2R2 < 22.2R3affected
Juniper NetworksJunos OS22.3R1 < 22.3R2-S2, 22.3R3affected
Juniper NetworksJunos OS22.4R1 < 22.4R2affected
Juniper NetworksJunos OS0 < 21.4unaffected

Weaknesses

  • CWE-754: CWE-754 Improper Check for Unusual or Exceptional Conditions

Workarounds

There are no known workarounds for this issue.

ADP Enrichment

CISA ADP Vulnrichment

  • SSVC:
  • Exploitation: none
    • Automatable: yes
    • Technical Impact: partial

CVE Program Container

Additional References

References