CVE-2024-1491
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
Summary
The devices allow access to an unprotected endpoint that allows MPFS file system binary image upload without authentication. The MPFS2 file system module provides a light-weight read-only file system that can be stored in external EEPROM, external serial flash, or internal flash program memory. This file system serves as the basis for the HTTP2 web server module, but is also used by the SNMP module and is available to other applications that require basic read-only storage capabilities. This can be exploited to overwrite the flash program memory that holds the web server's main interfaces and execute arbitrary code.
Affected Software
| Vendor | Product | Version Range | Status |
|---|---|---|---|
| Electrolink | Compact DAB Transmitter | 10W | affected |
| Electrolink | Compact DAB Transmitter | 100W | affected |
| Electrolink | Compact DAB Transmitter | 250W | affected |
| Electrolink | Medium DAB Transmitter | 500W | affected |
| Electrolink | Medium DAB Transmitter | 1kW | affected |
| Electrolink | Medium DAB Transmitter | 2kW | affected |
| Electrolink | High Power DAB Transmitter | 2.5kW | affected |
| Electrolink | High Power DAB Transmitter | 3kW | affected |
| Electrolink | High Power DAB Transmitter | 4kW | affected |
| Electrolink | High Power DAB Transmitter | 5kW | affected |
| Electrolink | Compact FM Transmitter | Compact FM Transmitter | affected |
| Electrolink | Compact FM Transmitter | 500W | affected |
| Electrolink | Compact FM Transmitter | 1kW | affected |
| Electrolink | Compact FM Transmitter | 2kW | affected |
| Electrolink | Modular FM Transmitter | 3kW | affected |
| Electrolink | Modular FM Transmitter | 5kW | affected |
| Electrolink | Modular FM Transmitter | 10kW | affected |
| Electrolink | Modular FM Transmitter | 15kW | affected |
| Electrolink | Modular FM Transmitter | 20kW | affected |
| Electrolink | Modular FM Transmitter | 30kW | affected |
| Electrolink | Digital FM Transmitter | 15W <= 40kW | affected |
| Electrolink | VHF TV Transmitter | BI | affected |
| Electrolink | VHF TV Transmitter | BIII | affected |
| Electrolink | UHF TV Transmitter | 10W <= 5kW | affected |
Weaknesses
- CWE-306: CWE-306 Missing Authentication for Critical Function
Workarounds
Electrolink has not responded to requests to work with CISA to mitigate these vulnerabilities. Users of the affected products are encouraged to contact Electrolink https://electrolink.com/contacts/ for additional information.
ADP Enrichment
CISA ADP Vulnrichment
- SSVC:
- Exploitation: none
- Automatable: no
- Technical Impact: total
CVE Program Container
Additional References
References
Feedback
Was this page helpful?
Glad to hear it! Please tell us how we can improve.