CVE-2022-40655
CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of NIKON NIS-Elements Viewer 1.2100.1483.0. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of ND2 files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15071.
Affected Software
| Vendor | Product | Version Range | Status |
|---|---|---|---|
| NIKON | NIS-Elements Viewer | 1.2100.1483.0 | affected |
Weaknesses
- CWE-122: CWE-122: Heap-based Buffer Overflow
ADP Enrichment
CVE Program Container
Additional References
- https://www.software-dl.microscope.healthcare.nikon.com/vuln/pdf/Vulnerabilities_on_NIS-Elements_Freeware_and_L_en_240917_02.pdf
- https://www.software-dl.microscope.healthcare.nikon.com/vuln/index.html
- https://www.zerodayinitiative.com/advisories/ZDI-22-1211/
CISA ADP Vulnrichment
- SSVC:
- Exploitation: none
- Automatable: no
- Technical Impact: total
References
Feedback
Was this page helpful?
Glad to hear it! Please tell us how we can improve.
Sorry to hear that. Please tell us how we can improve.