CVE-2022-40202

Summary

The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without authentication. This function allows the user to designate all function arguments and the file to be executed. This could allow the attacker to start any new process and achieve remote code execution.

Affected Software

VendorProductVersion RangeStatus
Delta ElectronicsInfraSuite Device Master0 <= 00.00.01aaffected

Weaknesses

  • CWE-306: CWE-306 Missing Authentication for Critical Function

ADP Enrichment

CVE Program Container

Additional References

CISA ADP Vulnrichment

  • SSVC:
  • Exploitation: none
    • Automatable: yes
    • Technical Impact: total