CVE-2022-22180

Summary

An Improper Check for Unusual or Exceptional Conditions vulnerability in the processing of specific IPv6 packets on certain EX Series devices may lead to exhaustion of DMA memory causing a Denial of Service (DoS). Over time, exploitation of this vulnerability may cause traffic to stop being forwarded, or a crash of the fxpc process. An indication of the issue occurring may be observed through the following log messages: Sep 13 17:14:59 hostname : %PFE-3: fpc0 (buf alloc) failed allocating packet buffer Sep 13 17:14:59 hostname : %PFE-7: fpc0 brcm_pkt_buf_alloc:393 (buf alloc) failed allocating packet buffer When Packet DMA heap utilization reaches 99%, the system will become unstable. Packet DMA heap utilization can be monitored using the command: user@junos# request pfe execute target fpc0 timeout 30 command "show heap" ID Base Total(b) Free(b) Used(b) % Name – ———- ———– ———– ———– — ———– 0 213301a8 536870488 387228840 149641648 27 Kernel 1 91800000 8388608 3735120 4653488 55 DMA 2 92000000 75497472 74452192 1045280 1 PKT DMA DESC 3 d330000 335544320 257091400 78452920 23 Bcm_sdk 4 96800000 184549376 2408 184546968 99 Packet DMA <<<< 5 903fffe0 20971504 20971504 0 0 Blob This issue affects: Juniper Networks Junos OS 18.4 versions prior to 18.4R2-S10, 18.4R3-S10 on EX2300 Series, EX2300-MP Series, EX3400 Series; 19.1 versions prior to 19.1R3-S7 on EX2300 Series, EX2300-MP Series, EX3400 Series; 19.2 versions prior to 19.2R1-S8, 19.2R3-S4 on EX2300 Series, EX2300-MP Series, EX3400 Series; 19.3 versions prior to 19.3R3-S5 on EX2300 Series, EX2300-MP Series, EX3400 Series; 19.4 versions prior to 19.4R3-S7 on EX2300 Series, EX2300-MP Series, EX3400 Series; 20.1 versions prior to 20.1R3-S3 on EX2300 Series, EX2300-MP Series, EX3400 Series; 20.2 versions prior to 20.2R3-S3 on EX2300 Series, EX2300-MP Series, EX3400 Series; 20.3 versions prior to 20.3R3-S2 on EX2300 Series, EX2300-MP Series, EX3400 Series; 20.4 versions prior to 20.4R3-S1 on EX2300 Series, EX2300-MP Series, EX3400 Series; 21.1 versions prior to 21.1R2-S2, 21.1R3 on EX2300 Series, EX2300-MP Series, EX3400 Series; 21.2 versions prior to 21.2R1-S2, 21.2R2 on EX2300 Series, EX2300-MP Series, EX3400 Series; 21.3 versions prior to 21.3R1-S1, 21.3R2 on EX2300 Series, EX2300-MP Series, EX3400 Series.

Affected Software

VendorProductVersion RangeStatus
Juniper NetworksJunos OS18.4 < 18.4R2-S10, 18.4R3-S10affected
Juniper NetworksJunos OS19.1 < 19.1R3-S7affected
Juniper NetworksJunos OS19.2 < 19.2R1-S8, 19.2R3-S4affected
Juniper NetworksJunos OS19.3 < 19.3R3-S5affected
Juniper NetworksJunos OS19.4 < 19.4R3-S7affected
Juniper NetworksJunos OS20.1 < 20.1R3-S3affected
Juniper NetworksJunos OS20.2 < 20.2R3-S3affected
Juniper NetworksJunos OS20.3 < 20.3R3-S2affected
Juniper NetworksJunos OS20.4 < 20.4R3-S1affected
Juniper NetworksJunos OS21.1 < 21.1R2-S2, 21.1R3affected
Juniper NetworksJunos OS21.2 < 21.2R1-S2, 21.2R2affected
Juniper NetworksJunos OS21.3 < 21.3R1-S1, 21.3R2affected
Juniper NetworksJunos OSunspecified < 18.4R2-S10, 18.4R3-S10unaffected

Weaknesses

  • CWE-754: CWE-754 Improper Check for Unusual or Exceptional Conditions
  • Denial of Service (DoS)

Workarounds

If IPv6 is not used in the environment, to prevent the issue an administrator can apply a firewall filter for blocking IPv6 packets on the ingress port where the traffic might be received: [firewall family ethernet-switching filter BLOCK-IPv6 interface-specific] [firewall family ethernet-switching filter BLOCK-IPv6 term 1 from ether-type ipv6] [firewall family ethernet-switching filter BLOCK-IPv6 term 1 then discard] [firewall family ethernet-switching filter BLOCK-IPv6 term 1 then count BLOCK-IPv6_COUNT] [firewall family ethernet-switching filter BLOCK-IPv6 term default then accept] [interfaces <interface ID> family ethernet-switching filter input BLOCK-IPv6]

ADP Enrichment

CVE Program Container

Additional References

References