CVE-2020-28400
7.5
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device.
Affected Software
| Vendor | Product | Version Range | Status |
|---|---|---|---|
| Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller | 0 < * | affected |
| Siemens | Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 | 0 < * | affected |
| Siemens | Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P | 0 < V4.7 | affected |
| Siemens | RUGGEDCOM RM1224 LTE(4G) EU | 0 < V6.4 | affected |
| Siemens | RUGGEDCOM RM1224 LTE(4G) NAM | 0 < V6.4 | affected |
| Siemens | SCALANCE M804PB | 0 < V6.4 | affected |
| Siemens | SCALANCE M812-1 ADSL-Router | 0 < V6.4 | affected |
| Siemens | SCALANCE M812-1 ADSL-Router | 0 < V6.4 | affected |
| Siemens | SCALANCE M816-1 ADSL-Router | 0 < V6.4 | affected |
| Siemens | SCALANCE M816-1 ADSL-Router | 0 < V6.4 | affected |
| Siemens | SCALANCE M826-2 SHDSL-Router | 0 < V6.4 | affected |
| Siemens | SCALANCE M874-2 | 0 < V6.4 | affected |
| Siemens | SCALANCE M874-3 | 0 < V6.4 | affected |
| Siemens | SCALANCE M874-3 3G-Router (CN) | 0 < V6.4 | affected |
| Siemens | SCALANCE M876-3 | 0 < V6.4 | affected |
| Siemens | SCALANCE M876-3 (ROK) | 0 < V6.4 | affected |
| Siemens | SCALANCE M876-4 | 0 < V6.4 | affected |
| Siemens | SCALANCE M876-4 (EU) | 0 < V6.4 | affected |
| Siemens | SCALANCE M876-4 (NAM) | 0 < V6.4 | affected |
| Siemens | SCALANCE MUM853-1 (A1) | 0 < V6.4 | affected |
| Siemens | SCALANCE MUM853-1 (B1) | 0 < V6.4 | affected |
| Siemens | SCALANCE MUM853-1 (EU) | 0 < V6.4 | affected |
| Siemens | SCALANCE MUM856-1 (A1) | 0 < V6.4 | affected |
| Siemens | SCALANCE MUM856-1 (B1) | 0 < V6.4 | affected |
| Siemens | SCALANCE MUM856-1 (CN) | 0 < V6.4 | affected |
| Siemens | SCALANCE MUM856-1 (EU) | 0 < V6.4 | affected |
| Siemens | SCALANCE MUM856-1 (RoW) | 0 < V6.4 | affected |
| Siemens | SCALANCE S615 EEC LAN-Router | 0 < V6.4 | affected |
| Siemens | SCALANCE S615 LAN-Router | 0 < V6.4 | affected |
| Siemens | SCALANCE W1748-1 M12 | 0 < V3.0.0 | affected |
| Siemens | SCALANCE W1748-1 M12 | 0 < V3.0.0 | affected |
| Siemens | SCALANCE W1788-1 M12 | 0 < V3.0.0 | affected |
| Siemens | SCALANCE W1788-2 EEC M12 | 0 < V3.0.0 | affected |
| Siemens | SCALANCE W1788-2 M12 | 0 < V3.0.0 | affected |
| Siemens | SCALANCE W1788-2IA M12 | 0 < V3.0.0 | affected |
| Siemens | SCALANCE W721-1 RJ45 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W721-1 RJ45 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W722-1 RJ45 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W722-1 RJ45 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W722-1 RJ45 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W734-1 RJ45 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W734-1 RJ45 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W734-1 RJ45 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W734-1 RJ45 (USA) | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W738-1 M12 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W738-1 M12 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W748-1 M12 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W748-1 M12 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W748-1 RJ45 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W748-1 RJ45 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W761-1 RJ45 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W761-1 RJ45 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W774-1 M12 EEC | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W774-1 M12 EEC | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W774-1 RJ45 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W774-1 RJ45 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W774-1 RJ45 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W774-1 RJ45 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W774-1 RJ45 (USA) | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W778-1 M12 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W778-1 M12 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W778-1 M12 EEC | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W778-1 M12 EEC (USA) | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W786-1 RJ45 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W786-1 RJ45 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W786-2 RJ45 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W786-2 RJ45 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W786-2 RJ45 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W786-2 SFP | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W786-2 SFP | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W786-2IA RJ45 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W786-2IA RJ45 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W788-1 M12 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W788-1 M12 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W788-1 RJ45 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W788-1 RJ45 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W788-2 M12 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W788-2 M12 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W788-2 M12 EEC | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W788-2 M12 EEC | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W788-2 M12 EEC | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W788-2 RJ45 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W788-2 RJ45 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE W788-2 RJ45 | 0 < V6.4.0 | affected |
| Siemens | SCALANCE X200-4P IRT | 0 < V5.5.0 | affected |
| Siemens | SCALANCE X201-3P IRT | 0 < V5.5.0 | affected |
| Siemens | SCALANCE X201-3P IRT PRO | 0 < V5.5.0 | affected |
| Siemens | SCALANCE X202-2IRT | 0 < V5.5.0 | affected |
| Siemens | SCALANCE X202-2P IRT | 0 < V5.5.0 | affected |
| Siemens | SCALANCE X202-2P IRT PRO | 0 < V5.5.0 | affected |
| Siemens | SCALANCE X204-2 | 0 < V5.2.5 | affected |
| Siemens | SCALANCE X204-2FM | 0 < V5.2.5 | affected |
| Siemens | SCALANCE X204-2LD | 0 < V5.2.5 | affected |
| Siemens | SCALANCE X204-2LD TS | 0 < V5.2.5 | affected |
| Siemens | SCALANCE X204-2TS | 0 < V5.2.5 | affected |
| Siemens | SCALANCE X204IRT | 0 < V5.5.0 | affected |
| Siemens | SCALANCE X204IRT PRO | 0 < V5.5.0 | affected |
| Siemens | SCALANCE X206-1 | 0 < V5.2.5 | affected |
| Siemens | SCALANCE X206-1LD | 0 < V5.2.5 | affected |
| Siemens | SCALANCE X208 | 0 < V5.2.5 | affected |
| Siemens | SCALANCE X208PRO | 0 < V5.2.5 | affected |
| Siemens | SCALANCE X212-2 | 0 < V5.2.5 | affected |
| Siemens | SCALANCE X212-2LD | 0 < V5.2.5 | affected |
| Siemens | SCALANCE X216 | 0 < V5.2.5 | affected |
| Siemens | SCALANCE X224 | 0 < V5.2.5 | affected |
| Siemens | SCALANCE X302-7 EEC (230V, coated) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X302-7 EEC (230V) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X302-7 EEC (24V, coated) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X302-7 EEC (24V) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X302-7 EEC (2x 230V, coated) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X302-7 EEC (2x 230V) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X302-7 EEC (2x 24V, coated) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X302-7 EEC (2x 24V) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X304-2FE | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X306-1LD FE | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X307-2 EEC (230V, coated) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X307-2 EEC (230V) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X307-2 EEC (24V, coated) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X307-2 EEC (24V) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X307-2 EEC (2x 230V, coated) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X307-2 EEC (2x 230V) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X307-2 EEC (2x 24V, coated) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X307-2 EEC (2x 24V) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X307-3 | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X307-3 | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X307-3LD | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X307-3LD | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X308-2 | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X308-2 | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X308-2LD | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X308-2LD | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X308-2LH | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X308-2LH | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X308-2LH+ | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X308-2LH+ | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X308-2M | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X308-2M | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X308-2M PoE | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X308-2M PoE | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X308-2M TS | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X308-2M TS | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X310 | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X310 | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X310FE | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X310FE | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X320-1 FE | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X320-1-2LD FE | 0 < V4.1.4 | affected |
| Siemens | SCALANCE X408-2 | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XB205-3 (SC, PN) | 0 < V4.3 | affected |
| Siemens | SCALANCE XB205-3 (ST, E/IP) | 0 < V4.3 | affected |
| Siemens | SCALANCE XB205-3 (ST, E/IP) | 0 < V4.3 | affected |
| Siemens | SCALANCE XB205-3 (ST, PN) | 0 < V4.3 | affected |
| Siemens | SCALANCE XB205-3LD (SC, E/IP) | 0 < V4.3 | affected |
| Siemens | SCALANCE XB205-3LD (SC, PN) | 0 < V4.3 | affected |
| Siemens | SCALANCE XB208 (E/IP) | 0 < V4.3 | affected |
| Siemens | SCALANCE XB208 (PN) | 0 < V4.3 | affected |
| Siemens | SCALANCE XB213-3 (SC, E/IP) | 0 < V4.3 | affected |
| Siemens | SCALANCE XB213-3 (SC, PN) | 0 < V4.3 | affected |
| Siemens | SCALANCE XB213-3 (ST, E/IP) | 0 < V4.3 | affected |
| Siemens | SCALANCE XB213-3 (ST, PN) | 0 < V4.3 | affected |
| Siemens | SCALANCE XB213-3LD (SC, E/IP) | 0 < V4.3 | affected |
| Siemens | SCALANCE XB213-3LD (SC, PN) | 0 < V4.3 | affected |
| Siemens | SCALANCE XB216 (E/IP) | 0 < V4.3 | affected |
| Siemens | SCALANCE XB216 (PN) | 0 < V4.3 | affected |
| Siemens | SCALANCE XC206-2 (SC) | 0 < V4.3 | affected |
| Siemens | SCALANCE XC206-2 (ST/BFOC) | 0 < V4.3 | affected |
| Siemens | SCALANCE XC206-2G PoE | 0 < V4.3 | affected |
| Siemens | SCALANCE XC206-2G PoE (54 V DC) | 0 < V4.3 | affected |
| Siemens | SCALANCE XC206-2G PoE EEC (54 V DC) | 0 < V4.3 | affected |
| Siemens | SCALANCE XC206-2SFP | 0 < V4.3 | affected |
| Siemens | SCALANCE XC206-2SFP EEC | 0 < V4.3 | affected |
| Siemens | SCALANCE XC206-2SFP G | 0 < V4.3 | affected |
| Siemens | SCALANCE XC206-2SFP G (EIP DEF.) | 0 < V4.3 | affected |
| Siemens | SCALANCE XC206-2SFP G EEC | 0 < V4.3 | affected |
| Siemens | SCALANCE XC208 | 0 < V4.3 | affected |
| Siemens | SCALANCE XC208EEC | 0 < V4.3 | affected |
| Siemens | SCALANCE XC208G | 0 < V4.3 | affected |
| Siemens | SCALANCE XC208G (EIP def.) | 0 < V4.3 | affected |
| Siemens | SCALANCE XC208G EEC | 0 < V4.3 | affected |
| Siemens | SCALANCE XC208G PoE | 0 < V4.3 | affected |
| Siemens | SCALANCE XC208G PoE (54 V DC) | 0 < V4.3 | affected |
| Siemens | SCALANCE XC216 | 0 < V4.3 | affected |
| Siemens | SCALANCE XC216-3G PoE | 0 < V4.3 | affected |
| Siemens | SCALANCE XC216-3G PoE (54 V DC) | 0 < V4.3 | affected |
| Siemens | SCALANCE XC216-4C | 0 < V4.3 | affected |
| Siemens | SCALANCE XC216-4C G | 0 < V4.3 | affected |
| Siemens | SCALANCE XC216-4C G (EIP Def.) | 0 < V4.3 | affected |
| Siemens | SCALANCE XC216-4C G EEC | 0 < V4.3 | affected |
| Siemens | SCALANCE XC216EEC | 0 < V4.3 | affected |
| Siemens | SCALANCE XC224 | 0 < V4.3 | affected |
| Siemens | SCALANCE XC224-4C G | 0 < V4.3 | affected |
| Siemens | SCALANCE XC224-4C G (EIP Def.) | 0 < V4.3 | affected |
| Siemens | SCALANCE XC224-4C G EEC | 0 < V4.3 | affected |
| Siemens | SCALANCE XF201-3P IRT | 0 < V5.5.0 | affected |
| Siemens | SCALANCE XF202-2P IRT | 0 < V5.5.0 | affected |
| Siemens | SCALANCE XF204 | 0 < V5.2.5 | affected |
| Siemens | SCALANCE XF204 | 0 < V4.3 | affected |
| Siemens | SCALANCE XF204 DNA | 0 < V4.3 | affected |
| Siemens | SCALANCE XF204-2 | 0 < V5.2.5 | affected |
| Siemens | SCALANCE XF204-2BA | 0 < V4.3 | affected |
| Siemens | SCALANCE XF204-2BA DNA | 0 < V4.3 | affected |
| Siemens | SCALANCE XF204-2BA IRT | 0 < V5.5.0 | affected |
| Siemens | SCALANCE XF204IRT | 0 < V5.5.0 | affected |
| Siemens | SCALANCE XF206-1 | 0 < V5.2.5 | affected |
| Siemens | SCALANCE XF208 | 0 < V5.2.5 | affected |
| Siemens | SCALANCE XM408-4C | 0 < V6.3.1 | affected |
| Siemens | SCALANCE XM408-4C (L3 int.) | 0 < V6.3.1 | affected |
| Siemens | SCALANCE XM408-8C | 0 < V6.3.1 | affected |
| Siemens | SCALANCE XM408-8C (L3 int.) | 0 < V6.3.1 | affected |
| Siemens | SCALANCE XM416-4C | 0 < V6.3.1 | affected |
| Siemens | SCALANCE XM416-4C (L3 int.) | 0 < V6.3.1 | affected |
| Siemens | SCALANCE XP208 | 0 < V4.3 | affected |
| Siemens | SCALANCE XP208 (Ethernet/IP) | 0 < V4.3 | affected |
| Siemens | SCALANCE XP208EEC | 0 < V4.3 | affected |
| Siemens | SCALANCE XP208PoE EEC | 0 < V4.3 | affected |
| Siemens | SCALANCE XP216 | 0 < V4.3 | affected |
| Siemens | SCALANCE XP216 (Ethernet/IP) | 0 < V4.3 | affected |
| Siemens | SCALANCE XP216EEC | 0 < V4.3 | affected |
| Siemens | SCALANCE XP216POE EEC | 0 < V4.3 | affected |
| Siemens | SCALANCE XR324-12M (230V, ports on front) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-12M (230V, ports on front) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-12M (230V, ports on rear) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-12M (230V, ports on rear) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-12M (24V, ports on front) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-12M (24V, ports on front) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-12M (24V, ports on rear) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-12M (24V, ports on rear) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-12M TS (24V) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-12M TS (24V) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-4M EEC (24V, ports on front) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-4M EEC (24V, ports on front) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-4M EEC (24V, ports on rear) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-4M EEC (24V, ports on rear) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-4M EEC (2x 24V, ports on front) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-4M EEC (2x 24V, ports on front) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-4M EEC (2x 24V, ports on rear) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-4M EEC (2x 24V, ports on rear) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-4M PoE (230V, ports on front) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-4M PoE (230V, ports on rear) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-4M PoE (24V, ports on front) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-4M PoE (24V, ports on rear) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324-4M PoE TS (24V, ports on front) | 0 < V4.1.4 | affected |
| Siemens | SCALANCE XR324WG (24 x FE, AC 230V) | 0 < V4.3 | affected |
| Siemens | SCALANCE XR324WG (24 X FE, DC 24V) | 0 < V4.3 | affected |
| Siemens | SCALANCE XR326-2C PoE WG | 0 < V4.3 | affected |
| Siemens | SCALANCE XR326-2C PoE WG (without UL) | 0 < V4.3 | affected |
| Siemens | SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) | 0 < V4.3 | affected |
| Siemens | SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) | 0 < V4.3 | affected |
| Siemens | SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) | 0 < V4.3 | affected |
| Siemens | SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) | 0 < V4.3 | affected |
| Siemens | SCALANCE XR328-4C WG (28xGE, AC 230V) | 0 < V4.3 | affected |
| Siemens | SCALANCE XR328-4C WG (28xGE, DC 24V) | 0 < V4.3 | affected |
| Siemens | SCALANCE XR524-8C, 1x230V | 0 < V6.3.1 | affected |
| Siemens | SCALANCE XR524-8C, 1x230V (L3 int.) | 0 < V6.3.1 | affected |
| Siemens | SCALANCE XR524-8C, 24V | 0 < V6.3.1 | affected |
| Siemens | SCALANCE XR524-8C, 24V (L3 int.) | 0 < V6.3.1 | affected |
| Siemens | SCALANCE XR524-8C, 2x230V | 0 < V6.3.1 | affected |
| Siemens | SCALANCE XR524-8C, 2x230V (L3 int.) | 0 < V6.3.1 | affected |
| Siemens | SCALANCE XR526-8C, 1x230V | 0 < V6.3.1 | affected |
| Siemens | SCALANCE XR526-8C, 1x230V (L3 int.) | 0 < V6.3.1 | affected |
| Siemens | SCALANCE XR526-8C, 24V | 0 < V6.3.1 | affected |
| Siemens | SCALANCE XR526-8C, 24V (L3 int.) | 0 < V6.3.1 | affected |
| Siemens | SCALANCE XR526-8C, 2x230V | 0 < V6.3.1 | affected |
| Siemens | SCALANCE XR526-8C, 2x230V (L3 int.) | 0 < V6.3.1 | affected |
| Siemens | SCALANCE XR528-6M | 0 < V6.3.1 | affected |
| Siemens | SCALANCE XR528-6M (2HR2, L3 int.) | 0 < V6.3.1 | affected |
| Siemens | SCALANCE XR528-6M (2HR2) | 0 < V6.3.1 | affected |
| Siemens | SCALANCE XR528-6M (L3 int.) | 0 < V6.3.1 | affected |
| Siemens | SCALANCE XR552-12M | 0 < V6.3.1 | affected |
| Siemens | SCALANCE XR552-12M (2HR2, L3 int.) | 0 < V6.3.1 | affected |
| Siemens | SCALANCE XR552-12M (2HR2) | 0 < V6.3.1 | affected |
| Siemens | SCALANCE XR552-12M (2HR2) | 0 < V6.3.1 | affected |
| Siemens | SIMATIC CFU DIQ | 0 < V2.0.0 | affected |
| Siemens | SIMATIC CFU PA | 0 < V2.0.0 | affected |
| Siemens | SIMATIC CM 1542-1 | 0 < V3.0 | affected |
| Siemens | SIMATIC CP 1604 | All Versions >= V2.7 | affected |
| Siemens | SIMATIC CP 1616 | All Versions >= V2.7 | affected |
| Siemens | SIMATIC CP 1626 | 0 < * | affected |
| Siemens | SIMATIC IE/PB-LINK | V3 < * | affected |
| Siemens | SIMATIC MV540 H | 0 < V3.0 | affected |
| Siemens | SIMATIC MV540 S | 0 < V3.0 | affected |
| Siemens | SIMATIC MV550 H | 0 < V3.0 | affected |
| Siemens | SIMATIC MV550 S | 0 < V3.0 | affected |
| Siemens | SIMATIC MV560 U | 0 < V3.0 | affected |
| Siemens | SIMATIC MV560 X | 0 < V3.0 | affected |
| Siemens | SIMATIC NET DK-16xx PN IO | All Versions >= V2.7 | affected |
| Siemens | SIMATIC Power Line Booster PLB, Base Module | 0 < * | affected |
| Siemens | SIMATIC PROFINET Driver | 0 < V2.3 | affected |
| Siemens | SIMATIC S7-1200 CPU 1211C AC/DC/Rly | 0 < V4.5.0 | affected |
| Siemens | SIMATIC S7-1200 CPU 1211C DC/DC/DC | 0 < V4.5.0 | affected |
| Siemens | SIMATIC S7-1200 CPU 1211C DC/DC/Rly | 0 < V4.5.0 | affected |
| Siemens | SIMATIC S7-1200 CPU 1212C AC/DC/Rly | 0 < V4.5.0 | affected |
| Siemens | SIMATIC S7-1200 CPU 1212C DC/DC/DC | 0 < V4.5.0 | affected |
| Siemens | SIMATIC S7-1200 CPU 1212C DC/DC/Rly | 0 < V4.5.0 | affected |
| Siemens | SIMATIC S7-1200 CPU 1212FC DC/DC/DC | 0 < V4.5.0 | affected |
| Siemens | SIMATIC S7-1200 CPU 1212FC DC/DC/Rly | 0 < V4.5.0 | affected |
| Siemens | SIMATIC S7-1200 CPU 1214C AC/DC/Rly | 0 < V4.5.0 | affected |
| Siemens | SIMATIC S7-1200 CPU 1214C DC/DC/DC | 0 < V4.5.0 | affected |
| Siemens | SIMATIC S7-1200 CPU 1214C DC/DC/Rly | 0 < V4.5.0 | affected |
| Siemens | SIMATIC S7-1200 CPU 1214FC DC/DC/DC | 0 < V4.5.0 | affected |
| Siemens | SIMATIC S7-1200 CPU 1214FC DC/DC/Rly | 0 < V4.5.0 | affected |
| Siemens | SIMATIC S7-1200 CPU 1215C AC/DC/Rly | 0 < V4.5.0 | affected |
| Siemens | SIMATIC S7-1200 CPU 1215C DC/DC/DC | 0 < V4.5.0 | affected |
| Siemens | SIMATIC S7-1200 CPU 1215C DC/DC/Rly | 0 < V4.5.0 | affected |
| Siemens | SIMATIC S7-1200 CPU 1215FC DC/DC/DC | 0 < V4.5.0 | affected |
| Siemens | SIMATIC S7-1200 CPU 1215FC DC/DC/Rly | 0 < V4.5.0 | affected |
| Siemens | SIMATIC S7-1200 CPU 1217C DC/DC/DC | 0 < V4.5.0 | affected |
| Siemens | SIMATIC S7-1200 CPU V4 family (incl. SIPLUS variants) | 0 < V4.5.0 | affected |
| Siemens | SIMOCODE pro V EIP 110-240V AC/DC | 0 < V1.1.3 | affected |
| Siemens | SIMOCODE pro V EIP 24V DC | 0 < V1.1.3 | affected |
| Siemens | SIMOCODE pro V PN 110-240V AC/DC | 0 < V2.1.3 | affected |
| Siemens | SIMOCODE pro V PN 24V DC | 0 < V2.1.3 | affected |
| Siemens | SIPLUS NET SCALANCE X308-2 | 0 < V4.1.4 | affected |
| Siemens | SIPLUS NET SCALANCE XC206-2 | 0 < V4.3 | affected |
| Siemens | SIPLUS NET SCALANCE XC206-2SFP | 0 < V4.3 | affected |
| Siemens | SIPLUS NET SCALANCE XC208 | 0 < V4.3 | affected |
| Siemens | SIPLUS NET SCALANCE XC216-4C | 0 < V4.3 | affected |
| Siemens | SIPLUS S7-1200 CPU 1212 AC/DC/RLY | 0 < V4.5.0 | affected |
| Siemens | SIPLUS S7-1200 CPU 1212 DC/DC/RLY | 0 < V4.5.0 | affected |
| Siemens | SIPLUS S7-1200 CPU 1212 DC/DC/RLY | 0 < V4.5.0 | affected |
| Siemens | SIPLUS S7-1200 CPU 1212C AC/DC/RLY | 0 < V4.5.0 | affected |
| Siemens | SIPLUS S7-1200 CPU 1212C DC/DC/DC | 0 < V4.5.0 | affected |
| Siemens | SIPLUS S7-1200 CPU 1212C DC/DC/DC | 0 < V4.5.0 | affected |
| Siemens | SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL | 0 < V4.5.0 | affected |
| Siemens | SIPLUS S7-1200 CPU 1214 AC/DC/RLY | 0 < V4.5.0 | affected |
| Siemens | SIPLUS S7-1200 CPU 1214 DC/DC/RLY | 0 < V4.5.0 | affected |
| Siemens | SIPLUS S7-1200 CPU 1214C AC/DC/RLY | 0 < V4.5.0 | affected |
| Siemens | SIPLUS S7-1200 CPU 1214C AC/DC/RLY | 0 < V4.5.0 | affected |
| Siemens | SIPLUS S7-1200 CPU 1214C DC/DC/DC | 0 < V4.5.0 | affected |
| Siemens | SIPLUS S7-1200 CPU 1214C DC/DC/DC | 0 < V4.5.0 | affected |
| Siemens | SIPLUS S7-1200 CPU 1214C DC/DC/DC | 0 < V4.5.0 | affected |
| Siemens | SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL | 0 < V4.5.0 | affected |
| Siemens | SIPLUS S7-1200 CPU 1214C DC/DC/RLY | 0 < V4.5.0 | affected |
| Siemens | SIPLUS S7-1200 CPU 1214C DC/DC/RLY | 0 < V4.5.0 | affected |
| Siemens | SIPLUS S7-1200 CPU 1214FC DC/DC/DC | 0 < V4.5.0 | affected |
| Siemens | SIPLUS S7-1200 CPU 1214FC DC/DC/RLY | 0 < V4.5.0 | affected |
| Siemens | SIPLUS S7-1200 CPU 1215 AC/DC/RLY | 0 < V4.5.0 | affected |
| Siemens | SIPLUS S7-1200 CPU 1215 AC/DC/RLY | 0 < V4.5.0 | affected |
| Siemens | SIPLUS S7-1200 CPU 1215 DC/DC/DC | 0 < V4.5.0 | affected |
| Siemens | SIPLUS S7-1200 CPU 1215 DC/DC/DC | 0 < V4.5.0 | affected |
| Siemens | SIPLUS S7-1200 CPU 1215 DC/DC/RLY | 0 < V4.5.0 | affected |
| Siemens | SIPLUS S7-1200 CPU 1215 DC/DC/RLY | 0 < V4.5.0 | affected |
| Siemens | SIPLUS S7-1200 CPU 1215 DC/DC/RLY | 0 < V4.5.0 | affected |
| Siemens | SIPLUS S7-1200 CPU 1215C AC/DC/RLY | 0 < V4.5.0 | affected |
| Siemens | SIPLUS S7-1200 CPU 1215C DC/DC/DC | 0 < V4.5.0 | affected |
| Siemens | SIPLUS S7-1200 CPU 1215FC DC/DC/DC | 0 < V4.5.0 | affected |
| Siemens | SIPLUS SIMOCODE pro V basic unit 2 | 0 < V1.1.3 | affected |
| Siemens | SOFTNET-IE PNIO | 0 < * | affected |
Weaknesses
- CWE-770: CWE-770: Allocation of Resources Without Limits or Throttling
ADP Enrichment
CISA ADP Vulnrichment
- SSVC:
- Exploitation: none
- Automatable: yes
- Technical Impact: partial
CVE Program Container
Additional References
- https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf
- https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03
- https://cert-portal.siemens.com/productcert/html/ssa-599968.html
References
- https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf
- https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03
- https://cert-portal.siemens.com/productcert/html/ssa-599968.html
Feedback
Was this page helpful?
Glad to hear it! Please tell us how we can improve.
Sorry to hear that. Please tell us how we can improve.