CVE-2020-10615
N/A
N/A
Summary
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication is not required to exploit this vulnerability.
Affected Software
| Vendor | Product | Version Range | Status |
|---|---|---|---|
| n/a | Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 | Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 | affected |
Weaknesses
- CWE-121: STACK-BASED BUFFER OVERFLOW CWE-121
ADP Enrichment
CVE Program Container
Additional References
- https://www.us-cert.gov/ics/advisories/icsa-20-105-03
- https://www.zerodayinitiative.com/advisories/ZDI-20-547/
References
- https://www.us-cert.gov/ics/advisories/icsa-20-105-03
- https://www.zerodayinitiative.com/advisories/ZDI-20-547/
Feedback
Was this page helpful?
Glad to hear it! Please tell us how we can improve.
Sorry to hear that. Please tell us how we can improve.