CVE-2019-25276
8.5
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Summary
Studio 5000 Logix Designer 30.01.00 contains an unquoted service path vulnerability in the FactoryTalk Activation Service that allows local users to potentially execute code with elevated privileges. Attackers can exploit the unquoted path in C:\Program Files (x86)\Rockwell Software\FactoryTalk Activation\ to inject malicious code that would execute with LocalSystem permissions.
Affected Software
| Vendor | Product | Version Range | Status |
|---|---|---|---|
| Rockwellautomation | Studio | 5000 | affected |
Weaknesses
- CWE-428: Unquoted Search Path or Element
ADP Enrichment
CISA ADP Vulnrichment
- SSVC:
- Exploitation: poc
- Automatable: no
- Technical Impact: total
References
- https://www.exploit-db.com/exploits/47676
- https://www.rockwellautomation.com/en_NA/overview.page
- https://www.vulncheck.com/advisories/studio-logix-designer-factorytalk-activation-service-unquoted-service-path