CVE-2019-13926
N/A
N/A
Summary
A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionality of the device.
Affected Software
| Vendor | Product | Version Range | Status |
|---|---|---|---|
| Siemens | SCALANCE S602 | All versions >= V3.0 and < V4.1 | affected |
| Siemens | SCALANCE S612 | All versions >= V3.0 and < V4.1 | affected |
| Siemens | SCALANCE S623 | All versions >= V3.0 and < V4.1 | affected |
| Siemens | SCALANCE S627-2M | All versions >= V3.0 and < V4.1 | affected |
Weaknesses
- CWE-400: CWE-400: Uncontrolled Resource Consumption
ADP Enrichment
CVE Program Container
Additional References
- https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf
- https://www.us-cert.gov/ics/advisories/icsa-20-042-10
References
- https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf
- https://www.us-cert.gov/ics/advisories/icsa-20-042-10
Feedback