CVE-2019-13924

Summary

A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.

Affected Software

VendorProductVersion RangeStatus
SiemensSCALANCE S602All versions < V4.1affected
SiemensSCALANCE S612All versions < V4.1affected
SiemensSCALANCE S623All versions < V4.1affected
SiemensSCALANCE S627-2MAll versions < V4.1affected
SiemensSCALANCE X-200 switch family (incl. SIPLUS NET variants)All versions < 5.2.4affected
SiemensSCALANCE X-200IRT switch family (incl. SIPLUS NET variants)All versions < V5.5.0affected
SiemensSCALANCE X-200RNA switch familyAll versions < V3.2.7affected
SiemensSCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)All versions < 4.1.3affected

Weaknesses

  • CWE-693: CWE-693: Protection Mechanism Failure

ADP Enrichment

CVE Program Container

Additional References

References