CVE-2017-20216
9.3
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Summary
FLIR Thermal Camera PT-Series firmware version 8.0.0.64 contains multiple unauthenticated remote command injection vulnerabilities in the controllerFlirSystem.php script. Attackers can execute arbitrary system commands as root by exploiting unsanitized POST parameters in the execFlirSystem() function through shell_exec() calls. Exploitation evidence was observed by the Shadowserver Foundation on 2026-01-06 (UTC).
Affected Software
| Vendor | Product | Version Range | Status |
|---|---|---|---|
| FLIR Systems, Inc. | FLIR Thermal Camera PT-Series | 8.0.0.64 | affected |
Weaknesses
- CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
ADP Enrichment
CISA ADP Vulnrichment
- SSVC:
- Exploitation: poc
- Automatable: yes
- Technical Impact: total
Additional References
References
- https://www.zeroscience.mk/en/vulnerabilities/ZSL-2017-5438.php
- https://www.exploit-db.com/exploits/42785/
- https://packetstormsecurity.com/files/144321
- https://cxsecurity.com/issue/WLB-2017090203
- https://web.archive.org/web/20171011125811/https://www.flir.com/security/blog/details/?ID=87043